POWER & EFFICIENCY REDEFINE UPS PERFORMANCE STANDARDS
 

• The Toronado Series 400 V Series Uninterruptible Power System (UPS) utilizes state-of-the-art design and construction to deliver industry-leading efficiency, reliability, performance, and flexibility to meet today’s critical power demands all over the world.

• Next-Generation IGBT Technology

• True On-Line, Double-Conversion UPS

• Parallel Up to Eight Units

• Input Power Factor > 0.99

• Input Current THD < 3%

• 100% Unbalanced Load Capability

• Wide Input Voltage Range +15%, -20% (Without Utilizing Batteries)

• High Efficiency for Lower Operational Cost

• Smallest Footprint & Highest Power Density in Industry

• Electronic Battery Isolation for Battery Longevity

• Generator-Friendly Design & Compatibility

• Complete Front-Access for Installation, Operation, & Service

• Handles Leading Power Factor Loads (Without Derating)

• SNMP/Web-Based Monitoring

• 380, 400, & 415 V 3- or 4-Wire, 50 or 60 Hz

• For Use With Transformerless Distribution or With All International Voltages

SMALLEST FOOTPRINT WITH HIGHEST POWER DENSITY

• A High Efficiency Design separates the Toronado Series from the competition. Efficiency greater than 92.5% at 20% loading means lower

power losses, reduced air conditioning needs, and reduced utility costs across a wide load range without sacrificing frequency or output voltage stability.

• A Transformer-Less Design allows the Toronado Series to be lighter with a smaller footprint. With its compact size, the Toronado Series has the highest energy density per square foot of any UPS of similar capacity.

 
 

ADVANCED FEATURES FOR MAXIMUM PERFORMANCE

• Fast-Switching IGBT Control Technology delivers up to 95.5% efficiency.

• A Full IGBT Rectifier & Harmonic Input Filter reduce input total harmonic distortion (THD) which also reduces heat loss in associated feed equipment and increases component life.

• An IGBT DC-to-DC Chopper produces lower DC ripple on the charging circuit, extending battery and capacitor life.

• A Hybrid Static-Bypass Switch offers the highest level of dependability.

• Improved Output Voltage Regulation provides superior transient response, easily handling 100% step loads without requiring battery support.

• A Generator-Friendly Design allows sizing of 1.1 kW generator capacities per 1.0 UPS kVA load.

• Units can be Paralleled up to eight modules for increased capacity and redundancy.

• Robustly Engineered Units are built using the highest quality components to ensure reliability.

HARDWARE OPTIONS

Batteries & Flywheels are two options for energy storage. The robust recharge circuitry of the Toronado Series allows use of VRLA batteries in matching cabinets or wet cell betteries without requiring a supplemental charger.

The Toronado Series UPS Tie Cabinet provides an attractive, simple landing point for a multi-module Toronado Series system’s output. Toshiba’s

solution is a smaller, lighter option with no control electronics compared to those offered by competitors. An optional 15-inch color LCD display is available for centralized monitoring of module and system status as a supplement to individual module monitors.

Maintenance Bypass Cabinets are available in wall-mount and standalone versions, as well as a custom designed slim-line version that matches the height and depth of the Toronado Series to seamlessly blend with the UPS.

 
 

MONITORING OPTIONS

RemotEye II® interface offers remote monitoring and analysis of UPS operation via HTTP and SNMP.

• Detailed Real-Time Status of UPS

• Email Notification of Status & Events

• Event & Alarm History Logging

• Remote Control of UPS via Internet Industrial Bus ProtoNode protocol adapter supports: Hard-Wired Remote Status Alarm Panel (RSAP) enables remotemonitoring of UPS alarm/status points up to 1000 feet away.

Model
Capacity100 // 160 // 225 // 300 // 500 // 650 // 750 // 1000 // 1330 // 1500 // 1660 // 2000
Power Watt90 // 144 // 202.5 // 300 // 500 // 650 // 750 // 1000 // 1330 // 1500 // 1660 // 2000
Input
Input Voltage Range(480V Three-Phase, Three-Wire + Ground Dual Input (20%to +15% (Without Using Battery
Input Power Factor>0.99 100-1000 // >0.98 1330-2000
Input Frequency Range60 +/- 10% Hz
Total Harmonic Distortion (THDi)<3% at 100% Load
Output
Output Voltage Range480 V: Three-Phase, Three-Wire + Ground
THD (THDv)<2% at 100% Linear Load, <5% at 100% non-linear load
Output Frequency Range60+/- 0.01% Hz
Overload CapacityInverter: 125% for 10 Minutes, 150% for 60 Seconds, Bypass: 1000% for 1 cycle (300-2000) // (100-300) Inverter: 125% for 2 Minutes, 150% for 60 Seconds, Bypass: 1000% for 1 cycle
Battery
Charge Value (C)-
Battery Power-
Internal Battery-
Communication
Communication Port-
Dry Contact-
Protocol-
Standards
QualityUL/CUL 1778 Listed, ISO 9001, ISO 14001, ANSI C62.41 (IEEE 587), FCC Class A-Article 47 - Part 15 B // UL/CUL 1778 Listed, ISO 9001, ISO 14001, ANSI C62.41 (IEEE 587), IEC 62040-2 Cat. C3
Performance-
EMC/LVD-
General
Running Temperature(32° to 104°F (0° to 40°C
Humidity5% to 95% Non-Condensing
Altitude7380 ft. (2250 m) Maximum Without Derating
Alerts-
Parallel Operation-
Net Weight (kg)350 // 390 // 490 // 1026 // 1497 // 1497 // 1928 // 2850 // 4350 // 5150 // 5350 // 6150
Dimensions (WxDxH) (mm)27.6*32.8*80.6 // 27.6*32.8*80.6 // 34.5*32.8*80.6 // 51.2*32.8*80.7 // 70.9*32.8*80.7 // 90.6*32.8*80.7 // 90.6*32.8*80.7 // 118.2*35.5*80.7 // 167.3*35.5*80.7 // 190.9*35.5*80.7 // 198.8*35.5*80.7 // 222.4*35.5*80.7